Hospital bed mattresses — foam, segmented and alternating-pressure air
Segmented foam mattresses and alternating-pressure air mattresses for pressure-injury prevention on hospital beds.
Which hospital bed mattresses does Keling manufacture?
Keling Medical manufactures 4 hospital bed mattress models: single-piece and segmented three-section foam mattresses that follow the articulation of an adjustable bed, and bubble-cell and tubular alternating-pressure air mattresses for pressure-injury prevention. All are sized to Keling bed surfaces and are CE marked.
All 4 mattresses
Filter by drive system, function count and load rating, or search within this category.




No products match those filters.
Try removing a filter, or tell us what you need — we manufacture nearly 200 varieties across ten product series and can quote items that are not listed here.
Mattresses specification comparison
Every model in this category, with the figures tenders ask for. Scroll the table sideways on a narrow screen, or print it for a tender file.
| Model | Product type | Construction | Inflation |
|---|---|---|---|
| KL-P001 Mattress | Hospital bed mattress | — | — |
| KL-P002 Mattress | Segmented hospital bed mattress | — | — |
| KL-P003 Air Mattress | Air mattress (bubble-cell, pressure-relief) | Bubble-cell (air-cell) | Electric pump (supplied) |
| KL-P004 Air Mattress | Air mattress (tubular cell, alternating pressure) | Tubular air-cell | Electric pump with digital controller (supplied) |
Common across this range: Mattress size 1900 × 900 mm; Application Applicable to a variety of hospital scenarios.
Specifications are subject to continuous improvement and dimensional tolerances apply — ask for the signed datasheet before issuing a purchase order or tender document.
What to decide first
The questions that most often change which model is the right one.
Match the mattress to the bed's articulation
On any bed with a backrest and knee-rest, specify a segmented three-section mattress. It folds where the bed folds instead of bridging across the break.
Match the size to the bed surface, not to the external size
The figure to quote is the bed surface dimension. Ordering against the bed's external size produces a mattress that is too large and rides up against the rails.
Alternating pressure where pressure injury is a clinical risk
Air mattresses cycle inflation between cells so that no area of skin carries load continuously. Specify them from the start for immobile, sedated or long-stay patients rather than buying them later after an injury has occurred.
Bubble-cell or tubular
Bubble-cell air mattresses are the economical choice for general pressure relief. Tubular alternating-pressure mattresses give a deeper, more controlled cycle and are the choice for higher-risk patients.
Confirm the cover specification
The cover is what survives cleaning, incontinence and repeated transfers. Ask for the cover material, whether it is vapour-permeable and whether it is welded or stitched — stitched seams are a fluid ingress path.
About this range
The mattress is the part of the bed the patient actually lies on, and it is the line most often cut from a tender to save money. That is a false economy twice over: beds delivered without mattresses sit unused until a second procurement round, and a mattress that does not match the bed undoes the positioning the bed was bought for.
Two mismatches cause most of the trouble. A single-piece flat mattress on an articulating bed bridges the joints when the backrest rises, which both reduces the effective angle and drags the patient's skin against the surface. And a mattress that does not match the bed surface dimension — commonly 1930 × 900 mm — leaves a gap at the head, foot or side that is an entrapment risk.